There are separate adjustments and a calibrated dial for each switch. Honeywell home aquastat controllerl4006a1967u the home depot. Works with circulator, low and highlimit or unit heat control. The honeywell aquastat controller is a strap on type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. The diff only talks to the lo control, it has nothing to do with the hi control. It has an external adjustment screw that permits easy setting and an immersion element that can be inserted horizontally or vertically. Controllers 602104s9 6 a some models include copper well or fitting. Choose from immersion controllers, universal electronic, multizone and dual aquastat controllers with a variety of temperature ranges and differentials and spst or spdt switching types. Honeywell l6006 series aquastat for highlowcirculator applications with adjustable 530f differential and 65f200f temperature range. It keeps the fan blower from running until the water heats. Check the honeywell homeresideo aquastat controller 65200 f range 530 f differential for circulator or highlow limit applications ratings before checking out. Buy honeywell l6006c1018 high or low limit circulator aquastat, 65200f range, 530f differential, stop factoryset at 200f, surface mount, no well. This honeywell l6006c1018 aquastat boiler control is an immersion type device that is used for restraining or balancing the temperature of liquids in boilers, storage tanks, and other applications. I have boiler that has a honeywell aquastat relay type l8148e mounted on the boiler.
Aquastat relay choices from grainger operate with a 24vac thermostat or a 750mv thermostat, depending on the model. Top 5 recommended honeywell l6006c aquastat manual. Features l4006, 7, and 8 provide spst switching for high or low limit or circulator control. Honeywell l6006c1018 aquastat, 1, color hvac controls. Regulates the temperature of liquids in boilers and storage tanks. Manuals and user guides for honeywell aquastat l6006. Settings for honeywell l6006c with hydroair we have a hydroair blower which has a honeywell l6006c 1018 aquatstat on the supply pipe at the coil. The aquastat monitors the water temperature in the boiler through the use of a copper bulb that stays in contact with the water inside the boiler and that shuts down the boiler automatically if the low or hightemperature set point is exceeded. Honeywell aquastat relay type l81483 im in the process of wiring honeywell hot watergas 3 zones honeywell 8043e to. Heating boiler aquastat control diagnosis, troubleshooting. Nov 02, 2018 hi i have a new thermostat honeywell rth6580wf that i am trying to connect to my aquastat l8148e via an aquastat l6006c. Manual reset aquastat controller with f to 270 f operating temperature and 66 in. Tradeline models are selected and packaged to provide ease of stocking, ease of handling, and maximum replacement value. Manuals for heating system controls for a list of aquastat.
There is a aquastat type l6006c clamped to the pipe coming out of the boiler it appears that this l6006c is contro read. He jumped the thermostat and then checked voltages all over the l8148e aquastat and found that the switching relay was not working properly. Honeywell aquastat relays grainger industrial supply. Settings for honeywell l6006c with hydroair heating help. Tradeline package with cross reference label and special instructions. But the differential setting on an aquastat adjusts the lo range temperature cutoff point when the burner is on. Available in horizontal, vertical and strapon mounting options and fixed, variable or manual reset differential temperature settings. Honeywell l6006c strap on limit switch high or low limit surface mount controller with spdt, operating range 65200f, factory stop at 200f overview the honeywell aquastat controller is a strap on type. Controllers 602104s10 2 ordering information when purchasing replacement and modernization products from your tradeline. It reveals the elements of the circuit as simplified forms, as well as the power as well as signal links in between the gadgets. Called the local heating guy and he came out to diagnose. The red wire of the 185 cable loops through the 6006c and. Honeywell aquastat l8148e switching relay heating help.
Honeywell l4006, l6006 single and multifunction aquastat. Boiler aquastat relay troubleshooting and control wiring. Aug 06, 2015 heating no domestic hot water honeywell aquastat duration. This surfacetype controller regulates the temperature in boilers and. Put the system into operation and observe the action of the device through. The aquastat uses an immersion system that has two switches. Insert the immersion sensing bulb through the bulb compression fitting. Your local honeywell automation and control products sales office check. Honeywell technical support information, product brochures and more. When mounting the l6006c, do not secure draw nut so tight that retainer clamp could. Aquastat temperature control the boiler aquastat controls the temperature of the water inside the boiler jacket. Honeywell l4008e aquastat high limit,manual reset, aquastat controller instructions honeywell l4006, manual reset strapon aquastat high limit control, 100 to 240 f we consider strap on controls less accurate and reliable than immersion type sensor controls. Specifications of super tradeline and tradeline controls are the same as those of standard models except as noted below.
Totally enclosed micro switch snapacting switches operate on temperature rise to set point. L6006,7,8 aquastat controllers product data features for vertical mounting and l4006, 7, and 8 provide spst switching for. Yes, after i looked again at the manual, that is the case. Tighten the adapter clamp screws so that the aquastat controller is firmly attached to the bulb compression. Multifunction aquastats l8148 honeywell l8148 aquastat relays. Shop honeywell strapon aquastat controllers for high or lowlimit and circulator temperature control at low prices at.
Jul 17, 2017 the aquastat on a hot water boiler is essentially a combination heating control. L6006,7,8 aquastat controllers product data features for. How do i wire a honeywell l6006c aquastat to a modine unit. View and download honeywell aquastat l4006a installation instructions manual online. Please sign in to your account to see your pricing, which may be different from the price displayed. Honeywell line voltage electric surfacemount or strap on aquastat with a 65200f spdt operating range adjustable 530f differential. This honeywell l6006c1018 aquastat boiler control is an immersion type device that is used for restraining or balancing the temperature of liquids in boilers, storage tanks, and other applications where temperature regulation is necessary.
An aquastat is a device commonly used to control water temperatures in. When mounting the l6006c, do not secure draw nut so tight that retainer clamp could collapse tubing. The honeywell aquastat is a controller designed for boiler water control in heating systems that are either oil or gas fired. Oct 12, 2018 but the differential setting on an aquastat adjusts the lo range temperature cutoff point when the burner is on. Factoryset stops at 180f, 240f, or 250f 82c, 116c, or 121c. Jul 17, 2017 the honeywell aquastat is a controller designed for boiler water control in heating systems that are either oil or gas fired. Honeywell l4041a,c pool heater aquastat controller instructions, also available at honeywell l4006, manual reset strapon aquastat high limit control, 100 to 240 f we consider strap on controls less accurate and reliable than immersion type sensor controls.
Hi i have a new thermostat honeywell rth6580wf that i am trying to connect to my aquastat l8148e via an aquastat l6006c. L6006 and l6007 aquastat controllers mcgill university. A wiring diagram is a streamlined conventional photographic representation of an electric circuit. Honeywell l6007, l6008, l6006, l4007, l4008 user manual. Nowadays, there are so many products of honeywell l6006c aquastat manual in the market and you are wondering to choose a best one. Adjust the adapter clamp so that the clamp fits over the groove at the opening of the bulb compression fitting.
Choose from immersion controllers, universal electronic, multizone and dual. This surfacetype controller regulates the temperature in boilers and tanks and is used for circulation along. These aquastat controllers operate in response to tem. The tradeline honeywell aquastat includes a bracket for strapon mounting, either vertically or horizontally. Due to high demand for honeywell home aquastat controller, temp. You have searched for honeywell l6006c aquastat manual. Honeywell l6006c1018 highlow limitcirculator strapon.
Honeywell honeywell limitedhoneywell limitoe 1985 douglas drive north 35 dynamic drive golden valley, mn 55422 scarborough, ontario m1v 4z9 checkout check to make certain that the aquastat controller was installed and adjusted properly. Summary of contents of user manual for honeywell l6006. The red wire of the 185 cable loops through the 6006c and then into the l8148e. Honeywell l6006c1018 homeresideo aquastat controller 65. We have 1 honeywell aquastat l6006 manual available for free pdf download. It reveals the elements of the circuit as simplified. Overview immersion type controllers for hydronic heating systems that turn off the burner whenever the boiler water temperature rises to the setpoint. Installation honeywell l6006 user manual page 12 of 20. One of the features of a hot water boiler aquastat is the lowlimit setting, which is either preset at the factory or adjusted by the homeowner on the.
L6006c caution do not replace immersion type aquastat controller with strapon aquastat controller. Honeywell l4080b52 high limit immersion aquastat, 100200f range, 8f differential note. Overview immersion type controllers for hydronic heating systems. L4006a1678 l4006a1678 high or low limit aquastat controller, spst, 3 in.
Single and multifunction aquastat controllers industrial. Boilers usually have tappings that allow the well to be mounted horizontally so boiler water of average temperature can circulate freely. Honeywell aquastat wiring diagram free wiring diagram. The aquastat uses an immersion system that has two switches controlling the high and low temperature limits on the heater.
The l6006c is whats known as an spdtswitched aquastat, which means that it can either make or break the connection on rise, depending on how you connect the wires to the terminals on the. Range 100 to 240f, availability is subject to change without notice. Im looking for information on wiring a honeywell l6006c aquastat for circulator. Honeywell l4006, l6006 single and multifunction aquastat controllers. L4006g includes two spst switches that provide high limit and circulator control.
On this website we recommend many designs abaout honeywell aquastat wiring diagram that we have collected from various sites home design, and of course what. The boiler aquastat is a device to a boiler like a thermostat is to an air conditioner, heat. View and download honeywell aquastat l8148a installation instructions manual online. The honeywell aquastat controller is an immersiontype device for limiting or regulating the temperature of liquids in boilers, storage tanks and other applications where temperature control is required. Apr 28, 2020 nowadays, there are so many products of honeywell l6006c aquastat manual in the market and you are wondering to choose a best one. I went down to the basement and noticed that the boiler would not fire, but the pump was on. Top 5 recommended honeywell l6006c aquastat manual simple home.
1334 1219 1551 389 781 927 53 1036 1431 1432 80 107 377 133 493 601 1077 652 1156 791 1241 194 1430 1547 1145 1187 419 542 842 264 172 333 341 1200 51 912 1481 175 1295 1463 779 231 347 1359 1066 697